Missouri Department of Transportation

Social Media Facebook Twitter Flickr Blog YouTube RSS

Standards and Specifications - Crashworthy End TerminalsQuadguard CZ

 

Energy Absorption  Quadguard CZ Website

Photos of Quadguard CZ xquadguard_cz.jpg (1723 bytes) xquadguard_cz1.jpg (1961 bytes)

Plan sheets of Quadguard CZ

Design Criteria of Quadguard CZ

Length Width
3.58 m (11'-9") [3 bay] 610 mm (2')
3.58 m (11'-9") [3 bay] 760 mm (2'-6")
6.33 m (20'-9") [6 bay] 610 mm (2')
6.33 m (20'-9") [6 bay] 760 mm (2'-6")

 

NCHRP-350
Test Level
Design
Velocity,
km/h (mph)
Number
of Bays
Effective
Length,
m (ft)
Number of Cartridges
Type I
Front of System
Type II
Rear of System
TL-2 70 (44) 3 3.57 (11.75) 2 2
TL-3 100 (62) 6 6.32 (20.75) 4 3

 

Number
of Bays
Nominal Width
610 mm (24") 760 mm (30")
3 QZ2403G QZ3003G
6 QZ2406G QZ3006G

quadguard_cz_model_number.jpg (23182 bytes)

Foundation Specifications

  1. Concrete Pad
    • Foundation:  150 mm (6") minimum depth P.C.C.
    • Anchorage:  MP-3® with 180 mm (7") studs 140 mm (5 1/2") embedment
  2. Asphalt over P.C.C.
    • Foundation:  75 mm (3") minimum asphaltic concrete over 75 mm (3") minimum P.C.C.
    • Anchorage:  MP-3® with 460 mm (18") studs 420 mm (16 1/2") embedment
  3. Asphalt over Subbase
    • Foundation:  150 mm (6") minimum asphaltic concrete over 150 mm (6") minimum compacted subbase
    • Anchorage:  MP-3® with 460 mm (18") studs 420 mm (16 1/2") embedment
  4. Asphalt Only
    • Foundation:  200 mm (8") minimum asphaltic concrete
    • Anchorage:  MP-3® with 460 mm (18") studs 420 mm (16 1/2") embedment

The documents are provided in Acrobat Reader format. Free Acrobat Reader download PDF Icon
About Us
How Do I...
Contact Us
Missouri Department of Transportation
Central Office
105 W. Capitol Avenue
Jefferson City, MO 65102
1-888-ASK-MODOT (275-6636)
horz_bar
| | |
Missouri State Government
© 2013 Missouri Department of Transportation. All Rights Reserved.   Privacy Policy.
 
 
 
 